1234 Maplewood Lane, Ferndale, MI (fictional) · 1,480 sq ft · Built 1952
Drafted from homeowner photos, reviewed by a real mechanical professional before delivery.
1. Replace the foil dryer vent with rigid metal duct — a genuine fire hazard and the one fix-first safety item in this report. $25–$60 in parts, or about $150 installed (Detroit-metro market).
2. Replace the washer's rubber supply hoses with braided stainless — plain rubber hoses are the burst risk we flag most; a burst supply line is one of the most common causes of major home water damage. Parts run $20–$40.
3. Start planning the furnace & AC replacement — the 2011 system runs on R-22 refrigerant, which is phased out and expensive to recharge. It's working today; the smart move is budgeting now so a failure in year 2–4 isn't a surprise. Planning estimates below.
4. Label breaker #14 in the panel — one unlabeled breaker. Flip it off, see what goes dark, label it, and add it to the panel map in the home file.
5. Keep an eye on the cast-iron drain stack — original to the house. No active leak found; budget for a camera inspection at the next plumbing visit.
Model ML180UH · Mfg 2011 (~15 yrs) · 80% AFUE · Working
Heat exchanger seams show no rust in the photos and the flame looks clean, but this furnace is paired with the R-22 air conditioner below — when one side goes, both usually get replaced together. Typical remaining life: 3–6 years with annual service. Filter: 16×25×1, replace every 90 days (already on the maintenance schedule).
Replacement planning (furnace + AC together, installed, estimates localized to the Detroit-metro market):
Good — standard-efficiency system: $9,500–$12,500 · Better — high-efficiency furnace, 16 SEER2 AC: $13,000–$17,000 · Best — variable-speed system with heat-pump hybrid: $17,500–$23,000 (rebate potential)
2.5-ton · R-22 refrigerant · Mfg 2011 (~15 yrs) · Working
Why it's flagged: R-22 was phased out of production in 2020. A recharge now costs several times what it used to, and a compressor failure on a 15-year-old R-22 unit is rarely worth repairing. Coil fins are mostly straight and the pad is level — keep 2 ft of clearance and let it run, but treat the replacement estimates above as a savings goal, not a someday idea.
Gas · Mfg 2019 (~7 yrs) · Expansion tank present ✓
No corrosion at the fittings, T&P discharge line routed correctly. Typical life 10–12 years — start budgeting in years 3–5. Flush it yearly; it's on the schedule.
When it eventually goes (planning estimates, Detroit-metro market, installed):
Good — standard tank: $1,700–$2,300 · Better — high-efficiency tank: $2,400–$3,200 · Best — heat-pump hybrid: $3,400–$4,600 (rebate potential)
Original cast iron (1952) · Basement section visible in photos
Surface rust and one older repair coupling at the base, but no active leak, sagging, or staining on the floor below. Cast iron of this age typically gives warning — slow drains, gurgling — before it fails. Have a plumber camera-inspect it at the next visit; sectional repair, if ever needed, runs far less than a full stack replacement, and planning for it beats an emergency call.
Pit clean · Check valve present ✓ · Discharge line clear
Test it twice a year — pour a bucket of water in the pit and confirm it kicks on and drains. It's on the schedule. If the basement is finished or stores anything valuable, a battery backup pump is cheap insurance against an outage during a storm.
200-amp service · No double-tapped breakers spotted · No corrosion or scorching
One flag: breaker #14 is unlabeled. Everything else on the panel map is identified — the labeled circuits from the homeowner's panel card:
| # | Amps | Controls |
|---|---|---|
| 4 | 30 | Dryer |
| 8 | 40 | Range |
| 12 | 20 | Kitchen outlets (GFCI) |
| 14 | 15 | Unlabeled — identify & label |
| 20 | 15 | Basement lights |
A 200A service has plenty of capacity for this home, including a future heat pump or EV charger.
Model WED4815 · ~2018 · Works fine
The fix-first item in this report: the vent-connection photo shows flexible foil venting. Foil vent traps lint in its ridges and is a genuine fire hazard — it's the single most common safety finding in HomeCheck reports. Swap to rigid or semi-rigid metal duct ($25–$60 in parts, an afternoon DIY or ~$150 for a pro) and clean the full vent run yearly. This is task #1 on the maintenance schedule.
Model WFW75HE · ~2018 · Works fine
The quiet risk in this laundry room: the supply hoses are plain rubber. Rubber hoses harden and crack with age, and a burst washer hose can release hundreds of gallons before anyone notices — it's one of the top causes of home water-damage claims. Replace with braided stainless hoses ($20–$40, hand-tools only, about 20 minutes). Leave the door ajar between loads to keep the front-load seal fresh.
2020 (~6 yrs)
Seals tight, no frost buildup in the freezer. Vacuum the coils every 6 months — on the schedule — and keep the water filter on a 6-month rotation for the dispenser.
Generated from this home's actual equipment. On the dashboard, each task can be marked done and the next due date sets itself.
| When | Task | For |
|---|---|---|
| Due now | Replace foil dryer vent with rigid metal duct | Dryer |
| Due now | Replace rubber washer hoses with braided stainless | Washer |
| Every 90 days | Replace furnace filter (16×25×1) | Lennox furnace |
| Fall | Flush the water heater | Rheem 50-gal |
| Spring & fall | Test the sump pump | Zoeller sump pump |
| Every 6 months | Clean refrigerator coils | Samsung fridge |
| Yearly | Clean the full dryer vent run | Dryer |
| Yearly | Test smoke & CO detectors; replace batteries | Whole home |
This report — and everything in your home's file — belongs to you. We keep it permanently, you can export it anytime, we never sell or share your home's information without your consent, and your file is never deleted if you stop using HomeCheck. It's your home's memory, not our hostage.
This is a sample report for a fictional home, prepared for illustration only. A real HomeCheck report is a planning snapshot built from homeowner photos, reviewed by a mechanical professional — HomeCheck is not a licensed home inspection. Cost figures are planning estimates localized to the Detroit-metro market from the home's address; actual quotes vary.
Get a report like this one for your home — your real equipment, your real score, your real priorities.
Get your HomeCheck → ← Back to HomeCheck